Conexão Flangeada: | DN 25 - 200 |
Pressão Nominal: | PN 16 - 40 |
Pressão de Entrada (P1): | 2 - 40 bar g |
Kvs: | 6 - 125 m3/h |
Temperatura: | 300 ºC |
Fluídos: | Líquidos e gases |
Self-acting back pressure regulators are simple control valves offering accurate control while being easy to install and maintain. They control the pressure upstream of the valve without requiring pneumatic or electrical control elements.
The UV 1.2 backpressure regulator is a spring-loaded, seat-controlled proportional control valve featuring diaphragm, piston or bellows relief. It is designed for simple control tasks and medium volumes. The valve cone can be fitted with a metallic or soft seal. The inlet pressure to be controlled is balanced across the valve seat by the force of the valve spring (set pressure). If the inlet pressure rises above the set pressure, the valve opens. With decreasing inlet pressure the valve control orifice reduces, when the pipeline is depressurised, the valve is closed. Rotating the adjusting screw clockwise increases the inlet pressure.
These valves are no shut-off elements ensuring a tight closing of the valve. In accordance with DIN EN 60534-4 and/or ANSI FCI 70-2 they may feature a leakage rate in closed position in compliance with the leakage classes III or V:
Leakage class III (metal sealing cone) = 0.1 % Kvs value
Leakage class V (soft seal cone) = 1.8 x 10-5 x Δp x D* [l/h]
*D=seat diameter
Para fazer o download do catálogo, clique aqui (em inglês).